The pressure relief valve is installed on the AP 25 line and it is normally adopted to discharge eventual peaks of pressure caused by fluids expansion due to
temperature variation.
The installation of this ihready to fitla kit is very easy and simple. Drill a hole into A, no bigger than the maximum diameter of 15 mm, deburr the hole edges, cleaning cut metal parts that may damage the Oring inside B.
Fit B on A, tightening the screws with a torque between 6 and 10 N.m. Connect C with a Rilsan 8/6 hose which brings fluid back to the tank. Relief pressure is adjustable by means of turning the bolt D.
Technical Data:
Maximum pressure: 270 bar
Flow rate max: 10 l/min
|